Whitwerx // CST Field Reference

Detector, PPE & Clinical Cross-Reference

CWA / TIC / TIM data across MultiRAE Pro, JCAD, MX908 & HAPSITE ER, CAP-1 (045135) canister/PPE guidance, exposure limits, decon notes, and field colorimetric methods.
REV: WORKING DRAFT
32 AGENTS/TICS LOGGED
DATA VERIFIED JUL 2026
Planning aid only, not a substitute for current TMs, manufacturer data, medical protocols, or unit SOPs. Detector capabilities are generalized by technology, not confirmed lab data for every compound. PPE recommendations are a starting reference; final level selection is an IC/Safety Officer call based on site-specific monitoring. Clinical information is for field recognition only and does not replace medical direction or your protocols.
Data provenance: exposure limits are drawn from the NIOSH IDLH database (cdc.gov/niosh/idlh) and the CDC/NCEH Chemical Warfare Agent Exposure Limits program (WPL/GPL/occupational IDLH, published for GB, VX and HD; GA/GD figures per ATSDR Medical Management Guidelines). Canister data is from the 3M/Scott CBRN CAP-1 (045135) technical datasheet. Where a specific figure was not located in these sources, the row says so explicitly rather than showing an estimated number. Compiled July 2026 — re-verify before relying on any single value operationally.
Detector gaps only (2+ platforms partial/no)
Detector
Detects
Partial
No ID
Rec. PPE
APR
LEVEL B
LEVEL A
Ops chart source
UNIT SOP verbatim from your risk matrix
DRAFT extrapolated, needs SO sign-off
Agent / TIC Rec. PPE MultiRAE Pro JCAD MX908 HAPSITE ER
Reference sources NIOSH Immediately Dangerous to Life or Health (IDLH) Values, cdc.gov/niosh/idlh · CDC/NCEH Chemical Warfare Agent Exposure Limits Fact Sheet · ATSDR Medical Management Guidelines (Nerve Agents GA/GB/GD/GF/VX) · 3M/Scott CBRN CAP-1 Canister (045135) Technical Datasheet & NIOSH CBRN APR/PAPR Certification Data · NRT Quick Reference Guide: Sarin (GB) · NIOSH Pocket Guide to Chemical Hazards (REL values) · RAE Systems/Honeywell Technical Note TN-106 (10.6 eV PID correction factors and ionization energies) · Unit C420 Operational Chart / safety officer risk matrix (canister swap time, recon/search time, critical infrastructure time, life safety time, and federal HAZMAT setup comparison for the original 10 SOP rows) · General CBRN medical management and field decontamination references. Row-level notes flag where a specific figure could not be located in these sources at time of compilation. Operational-chart fields marked DRAFT are extrapolated from the unit’s own tiering pattern and are not independently sourced.