CWA / TIC / TIM data across MultiRAE Pro, JCAD, MX908 & HAPSITE ER, CAP-1 (045135) canister/PPE guidance, exposure limits, decon notes, and field colorimetric methods.
REV: WORKING DRAFT
32 AGENTS/TICS LOGGED
DATA VERIFIED JUL 2026
Planning aid only, not a substitute for current TMs, manufacturer data, medical protocols, or unit SOPs.
Detector capabilities are generalized by technology, not confirmed lab data for every compound. PPE recommendations
are a starting reference; final level selection is an IC/Safety Officer call based on site-specific monitoring.
Clinical information is for field recognition only and does not replace medical direction or your protocols.
Data provenance: exposure limits are drawn from the NIOSH IDLH database (cdc.gov/niosh/idlh) and the
CDC/NCEH Chemical Warfare Agent Exposure Limits program (WPL/GPL/occupational IDLH, published for GB, VX and HD;
GA/GD figures per ATSDR Medical Management Guidelines). Canister data is from the 3M/Scott CBRN CAP-1 (045135)
technical datasheet. Where a specific figure was not located in these sources, the row says so explicitly rather
than showing an estimated number. Compiled July 2026 — re-verify before relying on any single value operationally.
Detector gaps only (2+ platforms partial/no)
Detector
Detects
Partial
No ID
Rec. PPE
APR
LEVEL B
LEVEL A
Ops chart source
UNIT SOP verbatim from your risk matrix
DRAFT extrapolated, needs SO sign-off
Agent / TIC
Rec. PPE
MultiRAE Pro
JCAD
MX908
HAPSITE ER
No agents match the current filters.
Reference sources
NIOSH Immediately Dangerous to Life or Health (IDLH) Values, cdc.gov/niosh/idlh ·
CDC/NCEH Chemical Warfare Agent Exposure Limits Fact Sheet ·
ATSDR Medical Management Guidelines (Nerve Agents GA/GB/GD/GF/VX) ·
3M/Scott CBRN CAP-1 Canister (045135) Technical Datasheet & NIOSH CBRN APR/PAPR Certification Data ·
NRT Quick Reference Guide: Sarin (GB) ·
NIOSH Pocket Guide to Chemical Hazards (REL values) ·
RAE Systems/Honeywell Technical Note TN-106 (10.6 eV PID correction factors and ionization energies) ·
Unit C420 Operational Chart / safety officer risk matrix (canister swap time, recon/search time, critical
infrastructure time, life safety time, and federal HAZMAT setup comparison for the original 10 SOP rows) ·
General CBRN medical management and field decontamination references.
Row-level notes flag where a specific figure could not be located in these sources at time of compilation.
Operational-chart fields marked DRAFT are extrapolated from the unit’s own tiering pattern and are not
independently sourced.